Tests were conducted on the Tampa Electric Company`s (TECo) Big Bend Station, Unit 4 flue gas desulfurization (FGD) system to evaluate an option for achieving high sulfur dioxide (SO{sub 2}) removal efficiencies. The option tested was the addition of dibasic acid (DBA) additive. In addition, the effectiveness of other potential options was simulated with the Electric Power Research Institute`s (EPRI) FGD PRocess Integration and Simulation Model (FGDPRISM) after it was calibrated to the system. An economic analysis was conducted to determine the cost effectiveness of each option considered.
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Main Title:
Results of DBA Additive Tests at Tampa Electric Company's Big Bend 4 FGD System
Description
Tests were conducted on the Tampa Electric Company`s (TECo) Big Bend Station, Unit 4 flue gas desulfurization (FGD) system to evaluate an option for achieving high sulfur dioxide (SO{sub 2}) removal efficiencies. The option tested was the addition of dibasic acid (DBA) additive. In addition, the effectiveness of other potential options was simulated with the Electric Power Research Institute`s (EPRI) FGD PRocess Integration and Simulation Model (FGDPRISM) after it was calibrated to the system. An economic analysis was conducted to determine the cost effectiveness of each option considered.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Results of DBA Additive Tests at Tampa Electric Company's Big Bend 4 FGD System,
report,
March 10, 1995;
Austin, Texas.