Effects of Introduced Materials in the Drift Scale Test

PDF Version Also Available for Download.

Description

Water samples previously acquired from superheated (>140 C) zones within hydrological test boreholes of the Drift Scale Test (DST) show relatively high fluoride concentrations (5-66 ppm) and low pH (3.1-3.5) values. In these high temperature regions of the rock, water is present superheated vapor only--liquid water for sampling purposes is obtained during the sampling process by cooling. Based on data collected to date, it is evident that the source of the fluoride and low pH is from introduced man-made materials (Teflon{trademark} and/or Viton{trademark} fluoroelastomer) used in the test. The test materials may contribute fluoride either by degassing hydrogen fluoride (HF) … continued below

Physical Description

12p

Creation Information

DeLoach, L & Jones, RL January 11, 2002.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Water samples previously acquired from superheated (>140 C) zones within hydrological test boreholes of the Drift Scale Test (DST) show relatively high fluoride concentrations (5-66 ppm) and low pH (3.1-3.5) values. In these high temperature regions of the rock, water is present superheated vapor only--liquid water for sampling purposes is obtained during the sampling process by cooling. Based on data collected to date, it is evident that the source of the fluoride and low pH is from introduced man-made materials (Teflon{trademark} and/or Viton{trademark} fluoroelastomer) used in the test. The test materials may contribute fluoride either by degassing hydrogen fluoride (HF) directly to produce trace concentrations of HF gas ({approx}0.1 ppm) in the high temperature steam, or by leaching fluoride in the sampling tubes after condensation of the superheated steam. HF gas is known to be released from Viton{trademark} at high temperatures (Dupont Dow Elastomers L.L.C., Elkton, MD, personal communication) and the sample water compositions indicate near stoichiometric balance of hydrogen ion and fluoride ion, indicating dissolution of HF gas into the aqueous phase. These conclusions are based on a series of water samples collected to determine if the source of the fluoride is from the degradation of materials originally installed to facilitate measurements. Analyses of these water samples show that the source of the fluoride is the introduced materials, that is the Viton{trademark} packers used to isolate test zones and/or Teflon{trademark} tubing used to draw water and steam from the test zones. In particular, water samples collected from borehole (BH) 72 high temperatures ({approx} 170 C) prior to introduction of any Viton{trademark} or Teflon{trademark} show pH Values (4.8 to 5.5) and fluoride concentrations well below 1 ppm over a period of six months. These characteristics are typical of condensing DST steam that contains only some dissolved carbon dioxide generated by water-mineral-gas reactions in the rock. With the introduction of the Viton{trademark} packer materials and Teflon{trademark} sampling tube in BH72, the water samples show pH values drop to 3.8, while fluoride rises to 2.4 ppm within three days. After nine days, the pH values reach as low as 3.4 and fluoride concentrations rise as high as 7.5 ppm in the collected samples. The background information describing the fluoride issue and a summary of the water collection activities along with the analytical results are provided below. The results of the field test confirm the hypothesis that the source of the fluoride in specific samples from the DST is the introduced test materials (i.e. Viton{trademark} and/or Teflon{trademark}). This is positive from the perspective of repository performance, particularly waste package and drip shield degradation behavior, as deleterious introduced materials would be avoided in an operating repository. Ongoing laboratory testing to be Completed in January 2002, and additional testing in BH72 and BH55 will address further details, such as the specific material introducing the fluorine and the material breakdown process.

Physical Description

12p

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • January 11, 2002

Added to The UNT Digital Library

  • Jan. 23, 2019, 12:54 p.m.

Description Last Updated

  • Jan. 25, 2019, 1:28 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 10

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

DeLoach, L & Jones, RL. Effects of Introduced Materials in the Drift Scale Test, report, January 11, 2002; Livermore, California. (https://digital.library.unt.edu/ark:/67531/metadc1411177/: accessed June 11, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen