The MFTF-B design includes a retractable getter system. Eight getter assemblies are planned (4 in each end plug). Electrically heated Ti wires are mounted on a telescoping insertion mechanism and, between machine shots (pulses), are extended into the chamber in the vicinity of inward-facing water-cooled magnet liners. During the shots, the sublimators must be withdrawn because they will intrude into plasma and diagnostic space. Each of the getter assemblies will be mounted on the exterior of the vacuum vessel. Bellows are used to keep essentially all of the mechanism isolated from the vessel vacuum. The bellows come in two sizes …
continued below
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
The MFTF-B design includes a retractable getter system. Eight getter assemblies are planned (4 in each end plug). Electrically heated Ti wires are mounted on a telescoping insertion mechanism and, between machine shots (pulses), are extended into the chamber in the vicinity of inward-facing water-cooled magnet liners. During the shots, the sublimators must be withdrawn because they will intrude into plasma and diagnostic space. Each of the getter assemblies will be mounted on the exterior of the vacuum vessel. Bellows are used to keep essentially all of the mechanism isolated from the vessel vacuum. The bellows come in two sizes (8.25'' O.D. and 14'' O.D.). The smaller of the two bellows has been qualified by testing up to 94,000 cycles by empirically adjusting details of the bellow design (geometry and thickness). The process required 12 different test samples and took over a one-year period to accomplish. The bellows consistently failed in the inside diameter weld heat-affected zone. Results from stress analysis studies are presented.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Tokarz, F. J.; Johnson, J. J.; Mukherjee, A. N. & Dalder, E. N.Stress analysis of MFTF-B getter system bellows. Final report,