Optimization of a VISAR for measuring flyer-plate velocities
Description:
VISAR (Velocity Interferometer System for Any Reflector) is commonly used for measuring flyer-plate velocities up to 6 km/s. Flyer plates can travel as much as 1 mm, which is large compared to usual depth-of-focus requirements for VISARs. Flyer plates are explosively driven, or driven by some other very energetic means; as such, they must be tested in a chamber, which will contain the explosion. Routing the laser beam to the chamber and the signal beam to the VISAR can be done safely and easily…
more
Date:
May 6, 1992
Creator:
Sweatt, W. C.; Crump, O. B., Jr. & Brigham, W. P.