Office of Scientific & Technical Information Technical Reports - 12 Matching Results

Search Results

open access

Allowable temperature rise in tubes of the piles: Precautions against boiling

Description: In the design of the pile, it was considered advisable never to impose so great a heat load on any tube that the available header pressure would be insufficient to sweep the tube free of vapor if boiling should accidentally be initiated in the tube. Figures are given for the maximum temperature rises permissible, as function of header pressure and orifice diameter.
Date: September 27, 1945
Creator: Woods, W. K.
Partner: UNT Libraries Government Documents Department
open access

The Average Q Meter

Description: The average Q meter is an instrument which averages the Q over over short periods of time, thus taking into account non-productive moments due to sparking and other factors, giving a truer measure of production than the present instantaneous meters. Embodied in this report are its methods of operation, reasons for its use, and descriptions of various physical types of the average Q meter.
Date: September 29, 1945
Creator: Bevis, M.; Osborne, M. J. & Winton, M. L.
Partner: UNT Libraries Government Documents Department
open access

Beta M2 Slit Support

Description: A new G slit support utilizing the standard G carbon now in use in all Beta production buildings was tested over approximately four months in the Pilot Plant with very successful results. A considerable saving has been made both in servicing time and in costs. The equipment has proved to be the best of any tried from the standpoint of run terminations due to alignment difficulties.
Date: September 7, 1945
Creator: Duncan, F. R.
Partner: UNT Libraries Government Documents Department
open access

Monsanto Chemical Company, Unit 3 abstracts of progress reports, August 16--31, 1945: Summary of work to date on volatile neutron source

Description: It was proposed to prepare a volatile polonium compound which could be used alone or with another gaseous compound as a neutron source. The objective was to obtain a neutron source which would give off few neutrons in the expanded state, but when condensed would act substantially as a thick target and emit perhaps ten times as many neutrons. Originally, polonium hexafluoride was suggested; with such compound the fluorine atoms would constitute the target. the predicted boiling point of polonium… more
Date: September 6, 1945
Creator: Rollinson, C.L.
Partner: UNT Libraries Government Documents Department