Reactor components P-11/K-15 re-inspection standards
Description:
The Mark 22 assemblies previously charged to the P Reactor as the P-11 charge, but never irradiated, are stored in borated racks in Building 105-K Assembly Area. The assemblies are stored inside aluminum cans into which they are placed and subsequently dried upon removal from the P-Reactor. This report discusses non-destructive examinations supplemented by destructive examination of a small number of these assemblies made to establish the acceptability of these assemblies for use as the K-15 ch…
more
Date:
August 25, 1992
Creator:
Banks, J.J.