Stress analysis of ultrasonic density detector for LOFT core inlet steady-state and LOCE conditions. Supplement 1
Description:
The UDD sensor bar with modified cross-section (0.0938-in. thick by 0.25-in. high overall) was analyzed to determine its resonant frequencies. Thermal and fluid-induced stresses due to steady-state and LOCE loads were also calculated. The sensor bar was shown not to be subject to vortex-shedding lock-in and was shown to meet applicable criteria of the ASME Boiler and Pressure Vessel Code. Seismic loads are insignificant compared to fluid loads.
Date:
April 25, 1979
Creator:
Mosby, W.R.
Item Type:
Refine your search to only