Measurement of critical temperature as a function of field
Description:
The critical temperature has been measured for various magnet conductors as a function of the perpendicular applied magnetic field. The isothermal environment was provided by a variable temperature cryostat which fits into the bore of a 10.0 tesla solenoid. The temperature gradient across the sample volume was measured to be less than 25 millikelvins. The superconducting the normal state transition was measured resistively, using sample current densities from 0.01 to 2 A/cm/sup 2/. The maximum …
more
Date:
April 23, 1983
Creator:
McInturff, A.D.; Ishibashi, K. & Heard, G.D.