45-day safety screen results and final report for tank 241-C-202, auger samples 95-Aug-026 and 95-Aug-027
Description:
Two auger samples from tank 241-C-202 (C-202) were received at the 222-S Laboratories and underwent safety screening analysis, consisting of differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity. Two samples were submitted for energetics determination by DSC. Within the triplicate analyses of each sample, one of the results for energetics exceeded the notification limit. The sample and duplicate analyses for both augers exceeded the notification lim…
more
Date:
June 19, 1995
Creator:
Baldwin, J.H.