Corrosion of delta plutonium in Rocky Flats tap water
Description:
Corrosion rates were established by measuring the weight loss of a sample completely immersed in tap water for specified periods of time. Tests were conducted for periods ranging from 21 to 1824 hours at ambient temperature in sealed 125-ml containers. The weight changes observed revealed that the corrosion of delta plutonium by tap water in a closed system occurs through two separate processes. Each results in a different average corrosion rate. Initially a typical diffusion-controlled surface…
more
Date:
September 10, 1979
Creator:
Hodges, A. E., III; Reynolds, J. J. & Haschke, J. M.