Production test IP-243-A-6-FP evaluation of X-8001 alloy aluminum components fabricated from cast blanks
Description:
This test is designed to accomplish two primary objectives: (1) to attempt to verify ex-reactor corrosion data which indicated improved corrosion resistance of cast blank X-8001 alloy material compared with wrought blank, and (2) to attempt to verify the resistance to groove pitting type of corrosion attack previously observed on M-388 components. Ex-reactor tests of cast blank M-388 alloy in autoclaves using water as the corrosive media up to 360 C, and in flow loops up to 120 C have indicated…
more
Date:
April 7, 1959
Creator:
Hall, R. E.