High Pressure Pump Seal Development

Description: "Test results indicated that graphite is not suitable for seal face material. A program to evaluate various materials and seal face geometries was initiated. A seal run using nucerite-bearium combination was carried on for six hours."
Date: March 5, 1962
Creator: Zanoni, P. J.
Partner: UNT Libraries Government Documents Department