Heat Transfer Rates for Cross-flow of Water Through a Tube Bank at Reynolds Numbers up to a Million: Part II. Circumferential Variation of Film Coefficient for Individual Tubes.
Description:
The tube bank used in this study consisted of 200 tubes, 10 wide and 20 deep. They were made of nickel, had an outside diameter and thickness of 0.810 and 0.063 inches, respectively, and were spaced on equilateral triangular corners, 1.28 inches apart. The purpose of the work was to determine the circumferential, or angular, variation of the film coefficient for individual tubes at various locations in the tube bank, with water flowing at 360°F and Reynolds numbers in the range 28,000 to 1,200,…