Search Results

open access

Evaluation of Buried Conduits as Personnel Shelters

Description: Supersedes ITR-1421. Twelve large-diameter buried conduit sections of various shapes were tested in the 60- to l49-psi overpressure region of Burst Priscilla to make an empirical determination of the degree of personnel protection afforded by commercially available steel and concrete conduits at depths of burial of 5, 7.5, and 10 feet below grade. Essentially, it was desired to assure that Repartment of Defense Class I, 100psi and comparable radiations, and Class II, 50-psi and comparable radia… more
Date: July 14, 1960
Creator: Albright, G. H.; LeDoux, J. C. & Mitchell, R. A.
Partner: UNT Libraries Government Documents Department
open access

Temperatures From Underground Detonation, Shot Rainier

Description: The results of temaperature measuring experiments conducted for Rainier shot, Operation Plumbbob are described, The temperature distribution in the surrounding tuff resulting from the detonation of an underground nuclear device yielding 1.7 kilotons of energy has been measured, Data indicate peak temperatures in the vicinity or 90 deg existing in the central regions which drop rapidly to approach ambient temperatures at distances of about l80 feet from the original ground zero, Based on measure… more
Date: July 1, 1958
Creator: Goodale, T. C.; Ragent, B.; Samuel, A. H.; Anderson, A. L.; Nielsen, D. E. & Olsen, J. L.
Partner: UNT Libraries Government Documents Department
open access

Test of Buried Structural-Plate Pipes Subjected to Blast Loading

Description: From abstract: Two 20-ft-long 7-ft-diameter 10-gauge structural-plate pipes, having longitudinal joints with eight bolts per foot, were buried and tested in the Smoky event of Operation Plumbbob at predicted pressure levels of 195 and 265 psi. The depth of burial was 10 ft over the crown of the pipe.
Date: July 28, 1961
Creator: Williamson, R. A. & Huff, P. H.
Partner: UNT Libraries Government Documents Department