Apparatus for the performanee testing of SNAP 10A thermoelectric elements was designed, constructed, and is now in operation. Elements may be tested for any desired length of tfme up to 1400 deg F and in a vacuum of 1 x 10/ sup -5/ of Hg. The equipment used for these tcsts may also be utilized for measuring Seebeck coefficient and resistance as a function of temperature. Element performance is derived from the data on voltages and temperatures. The performance variables which are reported in gr…