Clackamas 4800-foot thermal gradient hole: Cascade geothermal drilling: Final technical report
Description:
Thermal Power Company (Thermal) completed a thermal gradient hole to about 5000 feet (1524 m) total depth in Section 28, Township 8 South, Range 8 East, Willamette Meridian, Marion County, Oregon. The objective was to obtain data for the characterization of the deep hydrothermal regime in the Cascades volcanic region in order to better define its geothermal resource potential. The depth and location of the thermal gradient hole were designed by Thermal to test the basis of the Clackamas geother…
more
Date:
September 30, 1987
Creator:
Iovenitti, J.L. & D'Olier, W.L.
Partner: