Eta Temperature Effect
Description:
The temperature coefficient of eta has been measured with the thermal column of the Argonne pile using uranium foils of different isotopic ratios. The temperature change was effected by filtering neutrons through silver. The measured fractional change per degree centigrade is [formula].
Date:
February 25, 1944
Creator:
Bragdon, E. W.; Hughes, D. & Marshall, John