Diameter Measurements of Slugs Before and After Prolonged Heat Treatment

Description: Abstract: "Diameter measurements of 25 slugs taken before and after a prolonged heat treatment showed no evidence of differences that would indicate blistering. The average effects of the treatment was different for the various slugs. Large differences in diameter measurements between slugs. Large differences in diameter between slugs and significant differences between indices and positions were found."
Date: February 16, 1948
Creator: Bennett, Carl A. & Lane, J. J.
Partner: UNT Libraries Government Documents Department
open access

A Microdetermination of Uranium by Ferric Sulfate Titration

Description: Abstract: "Following nitrate removal by means of a three-stage hydrochloric acid digestion, uranium was reduced with chromous sulfate reagent. In an inert atmosphere, the quadrivalent uranium was titrated at 80-95[degrees] with standard ferric sulfate solution. The end point was obtained with a potentiometric cell including a platinum in-titrant reference electrode and a platinum indicator electrode. Application was made to various low leverl uranium solutions. For samples containing 1 - 12 mil… more
Date: February 16, 1949
Creator: Christopherson, E. W.
Partner: UNT Libraries Government Documents Department
open access

The Coulometric Titration of 8-Hydroxyquinoline

Description: Abstract: "A new method of determining 8-hydroxyquinoline by titration with electrolytucally-generated bromine has been developed. Results show good precision in the range 0.4 mg. to 1.6 mg. total 8-hydroxyquinoline, with 99% confidence limits of less than +/- 2%. An electronically-regulated constant current source, required by the method, is described. A new indicator system with high sensitivity to free bromine is discussed."
Date: June 16, 1949
Creator: Carson, W. N.
Partner: UNT Libraries Government Documents Department
open access

The Coulometric Determination of Acetic Acid

Description: Abstract: "Small amounts of acetic acid, equivalent to 400 ul. of 0.3 to 0.13 g/L. can be titrated coulonatrically in the presence of a 10 to 25-fold excess of HN03 in 70%, isopropanol. An accuracy of +/- 0.1% and a precision of +/- 8.5% (99% limite) are obtained.
Date: August 16, 1949
Creator: Carson, W. N. & Ko, Roy
Partner: UNT Libraries Government Documents Department
open access

Autoclaving of Anodized Slug Jackets

Description: The purpose of the test used to make this report was to determine if anodizing could become a part of the canning operation prior to autoclaving, other factors permitting, or if it must follow autoclaving.
Date: September 16, 1952
Creator: Dalrymple, R. S.
Partner: UNT Libraries Government Documents Department
open access

The Valve Actuated Pulse Column Design

Description: Abstract: "The valve-actuated pulse column is employed to give phase separation on each half cycle in the countercurrent flow cycle and provides independent control over each step in the cycle. The dependence on temperature of operation, on pulse frequency and amplitude, and on plate design and spacing has been studied for extraction and stripping of uranium with tributyl phosphate in a hydrocarbon diluent. It is found that the efficiency increases quite significantly as the temperature is rais… more
Date: February 16, 1953
Creator: Burger, L. L. & Clark, L. H.
Partner: UNT Libraries Government Documents Department
open access

A Description of the Acetone-Dye Solution Method of Demarcating a Leak Process Tubing While in the Pile

Description: Abstract: "A method has been devised and successfully used for marking a leaking pile process tube prior to its removal from the pile, such that subsequent location of the leak is more easily accomplished. An acetone solution of Testor's Dark Red Airplane Dope is poured into the suspect tube. The solution leaks from the hole and stains the surrounding area a light pink. To date the method has been used on tubes 3573F, 0486F, 0867F, and 3670F."
Date: July 16, 1952
Creator: DeHollander, W. R.
Partner: UNT Libraries Government Documents Department
open access

Decontamination of Dissolver Vent Gases at Hanford

Description: The preceding report follows an extensive study made at Hanford of methods and equipment to remove effectively the dissolver vent gases.
Date: February 16, 1951
Creator: Blasewitz, A. G.; Carlisle, R. V.; Judson, B. F.; Katzer, M. F.; Kurtz, E. F.; Schmidt, W. C. et al.
Partner: UNT Libraries Government Documents Department
open access

Minutes of Criticality Instrumentation Meeting Hanford Atomic Products Operation August 17 and 18, 1959

Description: At the request of the Hanford Operations Office of the Atomic Energy Commission, a criticality instrumentation meeting was held at Hanford on August 17 and 18, 1959. The purposes of the meeting were: (a) to review types of criticality control and/or alarm instrumentation at each site, their problems, shortcomings and potential obsolescence; (b) to discuss instrumentation in the area if approaching criticality; and (c) to consider for material balance purposes, the feasibility of devising instru… more
Date: September 16, 1959
Creator: Brown, C. L.
Partner: UNT Libraries Government Documents Department
open access

The Determination of Cu-64 in Reactor Effluent Water by Electrodeposition

Description: An analytical method for Cu-64 in reactor effluent has been studied based upon electrodeposition of the active copper with inert copper carrier. A two hour plating time was employed at a current density of 10 ma/sq cm and four volts across the cell. A stainless steel cathode plate was used. Carrier yields of greater than 80% were obtained with a standard deviation of the yield-corrected counting rate as low as 0.24%. Very little, if any contamination by other radioactive elements present wa… more
Date: September 16, 1953
Creator: Perkins, R. W. (Richard W.)
Partner: UNT Libraries Government Documents Department
open access

Some Comments on the Selection of Operating Temperatures for DPR

Description: The results of this investigation indicate that maximum electric power generation can be obtained by selecting the turbine steam temperature within a range of plus/minus 30 degrees C. from an "idealized" steam temperature. This "idealized" steam temperature is shown to depend primarily on the maximum permissible uranium temperature. The minimum available condenser temperature and the temperature rise of the coolant in the pile effect the selection of the turbine steam temperature to lesser ex… more
Date: November 16, 1953
Creator: Altmann, Manfred.
Partner: UNT Libraries Government Documents Department
open access

Filtration of Radioactive Aerosols by Glass Fibers: Part Two -- Appendices

Description: From introduction: "Five appendices, each of which pertains to a separate phase of the Filtration of Radioactive Aerosols by Glass Fibers program."
Date: April 16, 1951
Creator: Blasewitz, A. G.; Carlisle, R. V.; Judson, B. F.; Katzer, M. F.; Kurtz, E. F.; Schmidt, W. C. et al.
Partner: UNT Libraries Government Documents Department
open access

Recovery of Plutonium and Neptunium from Purex IWW by Anion Exchange

Description: The recovery of plutonium and neptunium by anion exchange has been well demonstrated on a laboratory scale. (1, 2,3,4) The specific adsorbed by the resin is the tetravalent hexanitrate complex of either element. With plutonium (IV) and neptunium(V) in IWW, the plutonium is adsorbed but the neptunium is not. If nitrite is used as the reductant in strong (preferably 8 M or over) nitric acid, both plutonium and neptunium are obtained in the tetravalent state, and both are adsorbed on the resin. Wi… more
Date: July 16, 1959
Creator: Van Tuyl, H. H.
Partner: UNT Libraries Government Documents Department
open access

Magnetic-Force Resistance Butt Wielding of Zircaloy-2 Fuel Element Closures

Description: Zircaloy-2 has a strong tendency to absorb oxygen and nitrogen at elevated temperatures. These gas impurities are extremely harmful, causing brittleness and loss of corrosion resistance. The production of ductile corrosion-resistant welds by present methods required shielding of the weld metal by an inert gas atmosphere or by a vacuum. The alternative to an inert gas atmosphere or a vacuum is reduction of the welding time to a few milliseconds of time to prevent gas absorption.
Date: November 16, 1959
Creator: Mills, L. E.
Partner: UNT Libraries Government Documents Department
open access

Use of Isolated Junction Sheathed Thermocouples for Moderator Temperature Measurements

Description: Two types of enclosed hot junction arrangements are possible with sheathed mineral insulated thermocouples. They are the integral junction and he isolated junction. The integral junction is formed by welding, soldering, brazing or forging the two wires into the end of the sheath. The process forms a good thermal and electrical contact between the three materials.
Date: June 16, 1960
Creator: Lovett, D. B.
Partner: UNT Libraries Government Documents Department