Search Results

open access

Liquid Observation Well (LOW) Functional Design

Description: This document presents the Functional Design Criteria for installing Liquid Observation Wells (LOWS) into single-shell tanks containing either ferrocyanide or organic waste. The LOWs will be designed to accommodate the deployment of gamma, neutron, and electromagnetic induction probes and to interface with the existing tank structure and environment.
Date: January 4, 1995
Creator: Paul, B.
Partner: UNT Libraries Government Documents Department
open access

Kaiser Engineers Hanford internal position paper -- Project W-236A, Multi-function Waste Tank Facility -- Peer reviews of selected activities

Description: The purpose of this paper is to develop and document a proposed position on the performance of independent peer reviews on selected design and analysis components of the Title 1 [Preliminary] and Title 2 [Final] design phases of the Multi-Function Waste Tank Facility [MWTF] project. An independent, third-party peer review is defined as a documented critical review of documents, data, designs, design inputs, tests, calculations, or related materials. The peer review should be conducted by person… more
Date: January 4, 1995
Creator: Stine, M. D.
Partner: UNT Libraries Government Documents Department
open access

Position paper -- Tank temperature element location

Description: The purpose of this paper is to develop and document a position on the number and location of temperature elements to be used in the Project W-236A, Multi-Function Waste Tank Facility (MWTF) waste storage tanks. The current preliminary design for the temperature element (TE) placement in the MWTF waste tanks is essentially a copy of the TE placement in existing Double-Shell Tanks (DST). The basis for the placement of these TEs in existing farms is not widely documented and was arrived at by con… more
Date: January 4, 1995
Creator: Groth, B. D.
Partner: UNT Libraries Government Documents Department
open access

Position paper -- Tank ventilation system design air flow rates

Description: The purpose of this paper is to document a project position on required ventilation system design air flow rates for the waste storage tanks currently being designed by project W-236A, the Multi-Function Waste Tank Facility (MWTF). The Title 1 design primary tank heat removal system consists of two systems: a primary tank vapor space ventilation system; and an annulus ventilation system. At the conclusion of Title 1 design, air flow rates for the primary and annulus ventilation systems were 960… more
Date: January 4, 1995
Creator: Goolsby, G. K.
Partner: UNT Libraries Government Documents Department
open access

Grout gas generation test plan

Description: Disclosed are detailed procedures for measuring the rate of gas generation by grout made from synthetic tanks wastes or actual tank material. Objective is to measure the rate of gas generation for various gases (H{sub 2}, N{sub 2}O, etc.) produced when grout, prepared using tank waste, is heated at 65 C. Experiments will also be conducted using grout from synthetic tank waste, as practice. Purpose is to provide data for evaluation of safety risks presented by gas generation in the grout vault a… more
Date: January 4, 1995
Creator: Person, J. C.
Partner: UNT Libraries Government Documents Department
open access

Radionuclide air emissions annual report for calendar year 1994

Description: This report presents the results of the Pinellas Plant air sampling program for the year of 1994. Topics discussed include: site description; source description; air emissions data; dose assessments; description of dose model; summary of input parameters of dose model; unplanned releases; and diffuse emissions. Included in the attachments of this document are: non-radon individual dose assessment; non-radon population dose assessment; summary of stack flow rate measurements; HOTSPOT computer mo… more
Date: April 4, 1995
Partner: UNT Libraries Government Documents Department
open access

D0 Silicon Upgrade: Helium and LN2 Storage Requirements for D-Zero Upgrade

Description: Calculations were done to determine a recommended size for the liquid helium storage dewar, gas helium storage tanks, and liquid nitrogen dewar requirements. I recommend a Liquid helium storage dewar with a nominal size of at least 2500 liters (660 gallons), preferably 3000 liters (792 gallons). I recommend obtaining gas helium storage tanks with a maximum allowable working pressure (MA WP) of 250 psig or greater. Combined volume to be at least 5880 cubic feet (44,000 gallons). I recommend obta… more
Date: April 4, 1995
Creator: Rucinski, Russ
Partner: UNT Libraries Government Documents Department
open access

D0 Silicon Upgrade: ASME Code and Pressure Calculations for Liquid Nitrogen Subcooler

Description: Included in this engineering note are three separate calculation divisions. The first calculations are the determination of the required thickness of the LN{sub 2} subcooler flat head according to ASME code. This section includes Appendix A-C. The minimum plate thickness determined was 0.563 in. The actual thickness chosen in fabrication was a 3/4-inch plate milled to 0.594-inch at the bolt circle. Along with the plate thickness, this section calculates the required reinforcement area at the to… more
Date: October 4, 1995
Creator: Kuwazaki, Andrew & Leicht, Todd
Partner: UNT Libraries Government Documents Department
open access

45-Day safety screen results for Tank 241-U-201, push mode, cores 70, 73 and 74

Description: Three core samples, each having two segments, from Tank 241-U-201 (U-201) were received by the 222-S Laboratories. Safety screening analysis, such as differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity were conducted on Core 70, Segment 1 and 2 and on Core 73, Segment 1 and 2. Core 74, Segment 1 and 2 were taken to test rotary bit in push mode sampling. No analysis was requested on Core 74, Segment 1 and 2. Analytical results for the TGA analyses … more
Date: May 4, 1995
Creator: Sathyanarayana, P.
Partner: UNT Libraries Government Documents Department
open access

EIA directory of electronic products. Second quarter 1995

Description: The Energy Information Administration (EIA) makes available for public use a series of machine-readable data files and computer models. They are available to the public on magnetic tapes; selected data files/models are available on diskette for IBM-compatible personal computers. This directory first presents the on-line files and compact discs. This is followed by descriptions and technical contacts and ordering and other information on the data files and models. An index by energy source is in… more
Date: October 4, 1995
Partner: UNT Libraries Government Documents Department
open access

Analysis of K-1 fan system for replacement of valve actuator, B Plant/Waste Encapsulation and Storage Facility

Description: Components of the K-1 fan system were evaluated for structural adequacy to accommodate an actuator weighing 540 lbs. The components evaluated were the connectors between the actuator and the valve, the duct between the valve and the facility wall, and the stud anchors connecting the duct to the facility wall. The loads were deadload, snow, operating loads, and seismic loads. The components were found to be structurally adequate for these loads.
Date: January 4, 1995
Creator: Burgess, J. S.
Partner: UNT Libraries Government Documents Department
open access

Position paper -- Continuous air monitor (CAM) acquisition recommendation

Description: The purpose of this position paper is to document the decision not to acquire continuous air monitors (CAM`s) from government excess/surplus supplies. The procurement plan for equipment to be acquired for project W-236A, the Multi-Function Waste Tank Facility (MWTF), stipulates that radiation monitoring equipment will be supplied by WHC via the stock retained within the excess/surplus inventory or utilization of procured instruments from canceled projects. Technological advances within the radi… more
Date: January 4, 1995
Creator: Hughes, M. E.
Partner: UNT Libraries Government Documents Department
open access

Evaluation of remaining life of the double-shell tank waste systems

Description: A remaining life assessment of the DSTs (double-shell tanks) and their associated waste transfer lines, for continued operation over the next 10 years, was favorable. The DST assessment was based on definition of significant loads, evaluation of data for possible material degradation and geometric changes and evaluation of structural analyses. The piping assessment was based primarily on service experience.
Date: May 4, 1995
Creator: Schwenk, E. B.
Partner: UNT Libraries Government Documents Department
open access

Foreign Direct Investment in the U.S.: Staging a Comeback?

Description: After four years of decline, foreign direct investment in the United States showed sharp gains in 1993 and 1994. Japan remained the largest foreign direct investor in the U.S. economy in 1993, despite a sharp slow down in investments by Japanese firms compared with British firms, the second largest direct investors. The overall foreign direct investment position in U.S. businessesand real estate - or the accumulated book value of all foreign investments - increased by $20 billion in 1993, nearl… more
Date: January 4, 1995
Creator: Jackson, James K.
Partner: UNT Libraries Government Documents Department
open access

Chemical Agent Attacks in Japan

Description: The release of the nerve agent Sarin in Tokyo's subway system on March 20, marks the first clearly non-state terrorist use of chemical weapons. The agent was highly diluted andmfatalities were relatively few (10), though the number of injured was substantial (5,000+, with 600 hospitalized). This incident clearly indicates the potential political effectiveness of chemical weapons against an unprotected civilian population. Once a population has been sensitized by an incident like this, even the … more
Date: May 4, 1995
Creator: Bowman, Steven R.
Partner: UNT Libraries Government Documents Department
open access

Characterization of Tank 48H Samples for Alpha Activity and Actinide Isotopics

Description: This document reports the total alpha activity and actinide isotopic results for samples taken from Tank 48H prior to the addition of sodium tetraphenylborate and MST in Batch {number_sign}1 of the ITP process. This information used to determine the quantity of MST for Batch {number_sign}1 of the ITP process and the total actinide content in the tank for dose calculations.
Date: December 4, 1995
Creator: Hobbs, D. T.; Coleman, C. J. & Hay, M. S.
Partner: UNT Libraries Government Documents Department
open access

Low-level waste vitrification phase 1 vendor test sample analysis data

Description: A multi-phase program was initiated in 1994 to test commercially available melter technologies for the vitrification of the low-level waste (LLW) stream from defense wastes stored in underground tanks at the Hanford Site in southeastern Washington State. Phase 1 of the melter demonstration tests was performed in vendor test facilities using simulated LLW and was completed during FY-1995. Test samples taken during Phase 1 testing were analyzed by independent laboratories who reported the analyse… more
Date: October 4, 1995
Creator: Mast, E.S.
Partner: UNT Libraries Government Documents Department
open access

Tank 241-AZ-101 steam bumping and settling Process Test report

Description: This report summarizes the process test in which the airlift circulators in Tank 241-AZ-101 were shutdown. The test was successful, in that no extreme temperature excursions occurred. Only general data was obtianed through the use of a gamma energy probe.
Date: December 4, 1995
Creator: Winkler, C. M.
Partner: UNT Libraries Government Documents Department
open access

Core sampling system spare parts assessment

Description: Soon, there will be 4 independent core sampling systems obtaining samples from the underground tanks. It is desirable that these systems be available for sampling during the next 2 years. This assessment was prepared to evaluate the adequacy of the spare parts identified for the core sampling system and to provide recommendations that may remediate overages or inadequacies of spare parts.
Date: April 4, 1995
Creator: Walter, E.J.
Partner: UNT Libraries Government Documents Department
open access

Tank 241-BX-106 tank characterization plan. Revision 1

Description: This document is a plan that identifies the information needed to address relevant issues concerning short-term and long-term safe storage and long-term management of Single-Shell Tank (SST) 241-BX-106.
Date: October 4, 1995
Creator: Homi, C. S.
Partner: UNT Libraries Government Documents Department
open access

Tank 241-C-103 tank characterization plan. Revision 2

Description: This document is a plan that identifies the information needed to address relevant issues concerning short-term and long-term safe storage and long-term management of Single-Shell Tank (SST) 241-C-103.
Date: October 4, 1995
Creator: Homi, C. S.
Partner: UNT Libraries Government Documents Department
Back to Top of Screen