Effective length measurements of prototype Main Injector Dipole endpacks
Description:
An endpack design has been developed for the Fermilab Main Injector Dipole. A major part of the design process was the testing of a series of prototype removable endpacks. The magnetic parameters that were tested included the effective length and the field shape variation. This report presents a description of the measurement techniques and the results for the effective length. The final endpack has an effective length at 1500 A (0.29T) of 2.6 [plus minus] 0.3 mm greater than the steel length, …
more
Date:
March 3, 1993
Creator:
Glass, H. D.; Brown, B. C. & Harding, D. J.
Partner: