NMR measurements in SSC dipole D00001
Description:
The first 16.5 m long SSC dipole magnet (D00001) had its field intensity measured as a function of position with a custom made NMR magnetometer. A short description of the probe is presented. The data obtained (most of it near 2 T spaced apart by one inch) shows an average transfer function of 1.02830 T/KA with position dependent values deviating from the average by up to .00130 T/KA revealing contruction inhomogeneities that were measured with a sensitivity of 25 ppM.
Date:
September 12, 1986
Creator:
Kuchnir, M.; Schmidt, E.E.; Hanft, R.W. & Strait, J.B.