UNT Libraries Government Documents Department - 11,762 Matching Results

Search Results

open access

1.1-meter bore, 8-Tesla test facility

Description: The design and fabrication of a 1.1-m bore superconducting coil for an 8- T facility at Lawrence Livermore Laboratory are discussed. This facility will provide the backing field required for testing large multifilamentary Nb$sub 3$Sn coils as part of the superconductor development program at Livermore. The magnet measures 1.85 m o.d., is 1.5 m in length, and is solenoid wound in four separate modules. Total cold weight of the assembly is 18,000 Kg. A NbTi superconductor is used throughout with … more
Date: November 19, 1975
Creator: Nelson, R.; Cornish, D.; Zbasnik, J.; Sackett, S. & Taylor, C.
open access

1. 5 GeV/c multiturn shaving extraction and its transport line for the Brookhaven AGS

Description: A system for fast shaving extraction at 1.5 GeV/c is implemented to extract the circulating beam in five turns. A numerical simulation is first carried out to determine the emittance and the rf structure of the extracted beam. This is followed by several machine study sessions which establish the optimal extraction configuration, confirm the emittance, and modify the transport line for low energy beam. Finally, a one-week run for the Neutrino Oscillation experiment demonstrates that the system … more
Date: January 1, 1979
Creator: Weng, W. T.; Blumberg, L. N.; Gill, E.; Soukas, A.; Witkover, R. L.; Egleman, E. et al.
open access

1.5 megawatt dc chopper power supplies for plasma shape control on Doublet III

Description: The Doublet III device is designed to study noncircular plasmas, including doublet and dee-shaped cross-sections. The plasma shape is determined by a system of 24 field-shaping coils which surround the vacuum vessel. Control of the magnetic flux linking these coils allows the plasma shape to be varied and controlled. This paper describes the high-speed dc chopper which is a major component of the field-shaping coil power system. The high-speed dc choppers, with a frequency response of up to 5 k… more
Date: November 1979
Creator: Rock, P. J. & Wesley, J. C.
open access

1/5-scale experiment of a Mark I boiling-water reactor pressure-suppression system under hypothetical LOCA conditions

Description: Experimental results show the sensitivity of hydrodynamically generated vertical loads to changes in the drywell pressurization rate, downcomer submergence, and vent-line loss coefficient. Insignificant effects on peak vertical loads were observed when the vent-line loss was varied. Peak vertical loads can be reduced by adding initial drywell overpressure so that the downcomers are partly cleared of water. Spatial variation of pressure at about the time of vent clearing is seen in comparisons o… more
Date: July 8, 1977
Creator: Pitts, J. H. & McCauley, E. W.
open access

1.06 μm 150 psec laser damage study of diamond turned, diamond turned/ polished and polished metal mirrors

Description: Using a well characterized 1.06 μm 150 ps glass laser pulse the damage characteristics for diamond turned, diamond turned/ polished, and polished copper and silver mirrors less than 5 cm diameter were studied. Although most samples were tested with a normal angle of incidence, some were tested at 45$sup 0$ with different linear polarization showing an increase in damage threshold for S polarization. Different damage mechanisms observed will be discussed. Laser damage is related to residual surf… more
Date: July 24, 1975
Creator: Saito, T. T.; Milam, D.; Baker, P. & Murphy, G.
open access

1 to 12 GeV/c beam transport for transverse or longitudinally polarized protons

Description: A two-stage beam transport for polarized protons has been constructed and operated at the Argonne ZGS. The first stage delivers vertically polarized protons (N-type) to an elastic scattering polarimeter consisting of a 10 cm long LH/sub 2/ target and two moveable sets of forward and recoil scintillation counters. The unscattered protons transported through the beam's second stage are focused onto the polarized proton target PPT-III; this target utilizes a 2.5 T R and A magnet to produce target … more
Date: January 1, 1979
Creator: Colton, E. P.
open access

2. 05 x 10/sup 9/ age of the Oklo uranium deposit

Description: U and Pb isotopic data on samples (10 to 100 gram) 2 to 10 m away from the borders of the Oklo reactor zones indicate a primary age of 2.05 x 10/sup 9/ years for the Oklo deposit and a secondary age of 0.375 x 10/sup 9/ years. All samples show effects of Pb loss; the average loss is 50 percent. Both the U--Pb and Pb isotopic data are consistent with a model of a primary 2.05 x 10/sup 9/ year age of the deposit, continuous volume diffusion of Pb from uraninite, and either continuous or recent lo… more
Date: January 1, 1977
Creator: Gancarz, A. J.
open access

2 meg-ampere prototype levitated coil for multipole fusion

Description: The coils major diameter is 1.0 meter and it occupies a cross-section which is about 0.2 meter minor in diameter. The prototype coil will carry four times the current of the largest such magnet built to date. As a result, the peak induction in the coil is about 8 T and the stored magnetic energy will be around 3 MJ. The paper describes the proposed Nb/sub 3/SN superconductor, the quench protection system which is based on the LBL shorted secondary concept, the isochroic refrigeration storage sy… more
Date: November 1, 1979
Creator: Green, M. A. & Glueck, R.
open access

2$sup 0$K vacuum pumping system for Baseball II

Description: A vacuum pumping system that provides a cryo surface for condensing and freezing of H/sub 2/ gas is described. A closed-loop vacuum system was designed and built at Lawrence Livermore Laboratory to pump down the neutralizer LH/sub e/ dewar with a volurae of 350 l and the lambda point dewar with a LH/sub e/ volume of 250 l. Both of these dewars can be pumped down simultaneously or one at a time. 100% of the H/sub e/ gas is recovered free of contaminations. The vacuum pump can handle 340 SCFM of … more
Date: August 20, 1973
Creator: Denhoy, B.S.
open access

3-D object reconstruction emission and transmission tomography with limited angular input

Description: The effects of the angular range of data taking in reconstructions in planar positron cameras using the deconvolution method and the matrix method, respectively, are investigated. It is found that in the absence of any a priori information there are undetermined components in the reconstruction if the field of view of the positron camera is limited. However, most of the undetermined components are recovered in the case in which the transverse spacing of the object is discrete, and all of them a… more
Date: October 1978
Creator: Tam, K. C.; Perez-Mendez, V. & Macdonald, B.
open access

3-dimensional beam scanning system for particle radiation therapy

Description: In radiation therapy treatment volumes up to several liters have to be irradiated. Today's charged particle programs use ridge filters, scattering foils, occluding rings collimators and boluses to shape the dose distribution. An alternative approach, scanning of a small diameter beam, is analyzed and tentative systems specifications are derived. Critical components are scheduled for fabrication and testing at LBL.
Date: March 1977
Creator: Leemann, C.; Alonso, J.; Grunder, H.; Hoyer, E.; Kalnins, G.; Rondeau, D. et al.
open access

4. pi. interferometric measurements of laser fusion targets

Description: Apparatus is described for rapidly manipulating a hollow glass microsphere laser fusion target and scanning the entire wall with a double pass interference microscope.
Date: September 29, 1977
Creator: Weinstein, B.W.; Willenborg, D.L.; Weir, J.T. & Hendricks, C.D.
open access

10. 6. mu. m damage threshold measurements on sub-one-hundred-ps pyroelectric detectors

Description: Sub-one-hundred-ps response time pyroelectric detectors are being developed at Los Alamos Scientific Laboratory (LASL) to be compatible with the 5-GHz oscilloscope direst-access mode of operation without damage. Strontium barium niobate, lithium tantalate, lanthanum-doped lead zirconate, and lithium niobate are being evaluated for use in the edge and coplanar configurations. Devices designed at LASL are compared with commercially available detectors. Test results of a less than 15-ps risetime, … more
Date: January 1, 1979
Creator: Stotlar, S. C.; McLellan, E. J.; Gibbs, A. J. & Webb, J.
open access

12. 5 MHz heavy ion linac for ion beam fusion

Description: Argonne National Laboratory (ANL) is currently developing the injector of a heavy ion beam driver for the inertial confinement fusion program. The first phase of the program is to accelerate about 20 mA of Xe/sup +1/ from a 1.5 MV preaccelerator 11.4 MeV in a low-beta RF linac. The first section of the linac utilizes a single harmonic buncher and independently-phased short linac resonators with a FODO magnetic quadrupole focusing lattice. These are followed by two double-stub Wideroee linacs. A… more
Date: 1979
Creator: Moretti, A.; Watson, J. M.; Moenich, J. S.; Foss, M. H.; Khoe, T. K.; Colton, E. P. et al.
open access

14'' x 17'' film recorder for computer-enhanced scans

Description: Physician acceptance of computer-enhanced radionuclide scan results, presented in the form of small Polaroid pictures, has been very limited for a number of subjective reasons. A new recorder was designed and constructed that presents the results of computer augmented scans through a medium that is quite familiar to doctors, the standard 14 in. x 17 in. x-ray film. (auth)
Date: January 1, 1976
Creator: Morris, A. C., Jr.; Barclay, T. R.; Akin, T. E.; Hansard, M. C.; Gibbs, W. D. & Modzelewski, C. U.
open access

15-foot bubble chamber characteristics

Description: Specifications, operation, characteristics, cost, and experience with the NAL 15-ft bubble chamber are described. Beam availability and some experimental proposals are discussed. (WHK)
Date: September 15, 1975
Creator: Huson, F. R.
open access

15 MeV neutron damage in Cu and Nb

Description: An investigation was made of high-energy neutron damage in Cu and Nb irradiated with approximately 15 MeV neutrons at the Oak Ridge Isochronous Cyclotron. The neutrons were generated by bombarding a thick Be target with 40- MeV deuterons resulting in a high energy neutron spectrum broadly peaked at 15 MeV. Single crystals of Cu and Nb were irradiated at room temperature to fluences of approximately 2 x 10$sup 17$ n/cm$sup 2$. The resulting loop-type defect clusters in the crystals were characte… more
Date: January 1, 1975
Creator: Roberto, J. B.; Narayan, J. & Saltmarsh, M. J.
open access

16. 3 eV neutron capture in /sup 107/Ag: nuclear structure of /sup 108/Ag. [Transitions, J correlations,. pi. ]

Description: The ..gamma.. rays from neutron capture in the 0- resonance of /sup 107/Ag at 16.3 eV were studied. Thirteen primary transitions populate spin 1 levels in /sup 108/Ag below an energy of 1.5 MeV. Transitions from low lying levels change in intensity by as much as a factor of 2 between thermal neutron capture (largely spin 1) and the 0- resonance, indicating a strong correlation of the population with level spin. 7 references.
Date: January 1, 1978
Creator: Orr, G. B.; Kane, W. R. & Smith, G. J.
open access

19 mm ballistic range: a potpourri of techniques and recipes

Description: The expansion of ballistic gun range facilities at LLL has introduced state-of-the-art diagnostic techniques to glovebox-enclosed ballistic guns systems. These enclosed ballistic ranges are designed for the study of one- dimensional shock phenomena in extremely toxic material such as plutonium. The extension of state-of-the-art phtographic and interferometric diagnostic systems to glovebox-enclosed gun systems introduces new design boundaries and performance criteria on optical and mechanical c… more
Date: September 23, 1975
Creator: Carpluk, G.T.
open access

24-MW neutral-beam injector of 400-keV H/sup 0/

Description: The negative and positive ion systems have both common goals and common problems. In fact, we have identified five items that must be developed before any large, neutral-beam injector, operating continuously or almost so, can be engineered. The five items are: (1) a continuous or almost continuous ion source, with 1A designating a source of positive ions and 1B a direct extraction source of negatives, (2) a recirculating metal-vapor cell, (3) a computer code with which to calculate beam traject… more
Date: November 1, 1979
Creator: Fink, J.H.; Hamilton, G.W. & Erickson, J.L.
open access

25 megajoule energy storage and delivery system for the Shiva laser

Description: A 25 megajoule, 20 kV capacitive energy storage and delivery system has been built and tested for Shiva--a 20 arm, 10 kJ, 20 TW neodymium glass fusion research laser. This system supplies over 3.5 megamperes to xenon flashlamps for optical pumping of the laser amplifier. About 15% of the energy is used to establish magnetic fields within Faraday rotator glass. A digital based control and diagnostics scheme is employed through the entire pulse power system. This scheme utilizes a distributed dig… more
Date: October 18, 1977
Creator: Gagnon, W.L.; Rupert, P. R.; Berkbigler, L.; Carder, B. M.; Gritton, D. G.; Holloway, R. W. et al.
open access

30-MJ superconducting magnetic energy storage (SMES) unit for stabilizing an electric transmission system

Description: Electric power systems that have major loads and generation centers separated by large distances may experience low-frequency power oscillations. This type of oscillation has occurred on the Pacific ac intertie that connects southern California and the Pacific Northwest. A separate, almost parallel, dc-transmission line also connects these areas. The Bonneville Power Administration, which operates this transmission system, has overcome the instability by controlling the power transmitted on the… more
Date: January 1, 1978
Creator: Rogers, J. D.; Boenig, H. J.; Bronson, J. C.; Colyer, D. B.; Hassenzahl, W. V.; Turner, R. D. et al.
Back to Top of Screen